Used to prevent water from freezing inside drainage lines. In industrial cooling units, it is wrapped around fan edges to melt the radiator. It can be used against all kinds of freezing in supermarket freezers, air conditioners, and aquariums.
Dinçel Drainage Resistance cables are designed to be installed inside pipes to drain water from defrost cooling equipment mounted in cold rooms.
They only operate during defrost cycles.
We recommend using a control device to ensure the long life of these resistors.
Note: The most commonly used power rating is 50 W/m. Additionally, we suggest using the 40 W/m range for plastic pipes.
These extremely flexible drainage heating cables are fast, safe, and very easy to use. Standard models or custom designs tailored to your needs overcome most installation challenges. For more information, contact Dinçel Resistance now.
Used to prevent water from freezing inside drainage lines. In industrial cooling units, it is wrapped around fan edges to melt the radiator. It can be used against all kinds of freezing in supermarket freezers, air conditioners, and aquariums.
All drainage resistors are manufactured according to demand.
They are produced at the desired power level according to our customers' requests.
Manufactured according to international standards at 50W/MT.
The hot zones vary according to demand, the cold zone is 1 meter.
Braided model.
GLASS FIBER DIAMETER (MM) | 1.1 |
HEATING WIRE | CHROME-NICKEL OR COPPER-NICKEL |
HEATING WIRE DIAMETER (MM) | 0.05-0.08 |
CABLE DIAMETER (MM) | 5X7 |
JACKET | SILICONE ELASTOMER |
TEMPERATURE RESISTANCE OF CABLE | -60 to 180 °C |
CABLE LENGTH RANGE (M) | 1-20 |
POWER (W) | 15-50 |
MAXIMUM VOLTAGE | 500 |
TOLERANCE VALUES | POWER +/-10% LENGTH +/- 1% DIMENSION +/-0.2mm |
```