Unbraided Ellipse Drain 3

Unbraided Ellipse Drain 3

Dinçel Drainage Resistance cables are designed to be installed inside pipes to drain water from defrost cooling equipment mounted in cold rooms.

They operate only during defrost cycles.

We recommend using a control device to ensure the long life of these resistors.

Note: The most commonly used power rating is 50 W/m. Additionally, for plastic pipes, we advise using the 40 W/m range.

These extremely flexible drainage heating cables are fast, safe, and very easy to use. Standard models or custom designs according to your needs overcome most of the problems you may encounter during installation. For more information, contact Dinçel Resistance now.

  • Usage Areas

    It is used inside drainage pipes to prevent water from freezing. In industrial cooling units, it is wrapped around fan edges to melt the radiator. It can be used against all kinds of freezing in market freezers, air conditioners, and aquariums.

  • Technical Specifications

    All drainage heaters are manufactured on demand.

    They are produced with the requested power according to our customers' needs.

    Manufactured at 50W/m according to world standards.

    The hot zones vary according to demand, the cold zone is 1 meter.

    It is an unbraided model.

    GLASS FIBER DIAMETER (MM) 1.1
    HEATING WIRE CHROME-NICKEL OR COPPER-NICKEL
    HEATING WIRE DIAMETER (MM) 0.05-0.08
    CABLE DIAMETER (MM) 5X7
    COATING SILICONE ELASTOMER
    COATING SILICONE ELASTOMER
    TEMPERATURE RESISTANCE OF CABLE -60 to 180
    CABLE LENGTH RANGE (M) 1-20
    POWER (W) 15-50
    MAXIMUM VOLTAGE 500
    TOLERANCE VALUES POWER +/-10%
    LENGTH +/- 1%
    SIZE +/-0.2mm